ISO/IEC 17025 and ISO 17034 Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or any other quality control processes used to determine flash point, applicable for the test method ASTM D93, or test methods IP 34, ISO 2719, or other applicable methods.  

ISO 17025 & ISO 17034 Flash Point Secondary Working Standard, Cleveland Open Cup (COC) ARO's Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials have been characterised in accordance with ASTM D93 Procedure A, or equivalent test method. Manufacturing, testing and certification has been performed in accordance with ARO's accreditation to ISO/IEC 17025 and ISO 17034, UKAS CAB No. 27393.

Availability: In stock
SKU
CRM-PMGO01

File(s)

ISO/IEC 17025 and ISO 17034 Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or any other quality control processes used to determine flash point, applicable for the test method ASTM D93, or test methods IP 34, ISO 2719, or other applicable methods.

ISO/IEC 17025 / ISO 17034 certified Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials are tested and certified in accordance with ASTM D93 'Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester Procedure A', or equivalent test method.

  • • Manufactured and Characterised in strict accordance to ISO/IEC 17025 and ISO 17034 under UKAS accreditation
  • • Highest level of accreditation guarantee, providing the most credible certified data available worldwide
  • • Characterisation using data by ISO/IEC 17025 accredited laboratories
  • • Fully traceable to International Standards
  • • Supplied in tamper-evident UN compliant packaging, providing assurance of sample integrity
  • • Pack size 250 mL
  • • Manufactured in the United Kingdom by ARO Scientific Ltd
  • • 12 Month shelf life

These flash point certified reference materials are used for verification of apparatus typically used in, but not limited to, the determination of the flash point of petroleum products in the temperature range from 40 °C to 370 °C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus.

Our commitment to quality and our accreditations demonstrates that we have rigorous quality systems in place that allow us to provide customers with the highest quality products possible, which are accepted globally. In addition, our Combined UKAS and ILAC-MRA Mark demonstrates that the accreditation we hold is recognised under the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement, our certificates are accepted around the world.

More Information
Lead-time Dispatched within 24 business hours
Certification ISO 17025 / ISO 17034
Certified Value 65.4 °C
Matrix Diesel
Pack Size 250 mL
Dangerous Goods Yes
UN Number UN 1202
Packing Group III
Shipping Name DIESEL FUEL, GAS OIL OR HEATING OIL, LIGHT
Transport Class 3

File(s)